Schedule 100 steel pipe: outside diameter, wall thickness and weight chart

Schedule 100 in ASME B36.10M gives one wall for each size, from 8 inch to 24 inch. The outside diameter is that of the size, the same in every schedule; the inside diameter is the outside diameter less two walls.

Size OD Wall ID Weight
8 inch (DN 200) 219.1 mm (8.625 in) 15.09 mm (0.594 in) 188.92 mm (7.437 in) 75.92 kg/m (51.00 lb/ft)
10 inch (DN 250) 273.0 mm (10.750 in) 18.26 mm (0.719 in) 236.48 mm (9.312 in) 114.71 kg/m (77.10 lb/ft)
12 inch (DN 300) 323.8 mm (12.750 in) 21.44 mm (0.844 in) 280.92 mm (11.062 in) 159.87 kg/m (107.42 lb/ft)
14 inch (DN 350) 355.6 mm (14.000 in) 23.83 mm (0.938 in) 307.94 mm (12.124 in) 194.98 kg/m (130.98 lb/ft)
16 inch (DN 400) 406.4 mm (16.000 in) 26.19 mm (1.031 in) 354.02 mm (13.938 in) 245.57 kg/m (164.98 lb/ft)
18 inch (DN 450) 457 mm (18.000 in) 29.36 mm (1.156 in) 398.28 mm (15.688 in) 309.64 kg/m (208.15 lb/ft)
20 inch (DN 500) 508 mm (20.000 in) 32.54 mm (1.281 in) 442.92 mm (17.438 in) 381.55 kg/m (256.34 lb/ft)
22 inch (DN 550) 559 mm (22.000 in) 34.93 mm (1.375 in) 489.14 mm (19.250 in) 451.45 kg/m (303.16 lb/ft)
24 inch (DN 600) 610 mm (24.000 in) 38.89 mm (1.531 in) 532.22 mm (20.938 in) 547.74 kg/m (367.74 lb/ft)

Plain-end weight of carbon steel pipe, by the standard's own formula: 10.69 × (D − t) × t in lb/ft, with D and t in inches (0.0246615 × (D − t) × t in kg/m, in mm). Austenitic stainless weighs about 2% more.

Questions

What is schedule 100 pipe?
It is the schedule 100 wall series in ASME B36.10M: one wall for each size, from 8 inch to 24 inch. The outside diameter is that of the size, and the inside diameter is the outside diameter less two walls.
How do you calculate the weight of schedule 100 pipe?
With the standard's own formula: weight in lb/ft = 10.69 × (D − t) × t, with the outside diameter D and the wall t in inches; in kg/m, 0.0246615 × (D − t) × t in millimetres. That is carbon steel; austenitic stainless weighs about 2% more.