Skip to content

24 inch pipe (DN 600): outside diameter, wall thickness and weight by schedule

A 24 inch pipe (DN 600) has a 610 mm (24.000 in) outside diameter in every schedule: what changes is the wall, and with it the inside diameter and the weight. Designations that give the same wall share a row.

Schedule Wall ID Weight
Sch 5 / 5S 5.54 mm (0.218 in) 598.92 mm (23.564 in) 82.58 kg/m (55.42 lb/ft)
Sch 10 / 10S 6.35 mm (0.250 in) 597.30 mm (23.500 in) 94.53 kg/m (63.47 lb/ft)
Sch 20 / STD / 40S 9.53 mm (0.375 in) 590.94 mm (23.250 in) 141.12 kg/m (94.71 lb/ft)
XS / 80S 12.70 mm (0.500 in) 584.60 mm (23.000 in) 187.07 kg/m (125.61 lb/ft)
Sch 30 14.27 mm (0.562 in) 581.46 mm (22.876 in) 209.65 kg/m (140.81 lb/ft)
Sch 40 17.48 mm (0.688 in) 575.04 mm (22.624 in) 255.43 kg/m (171.45 lb/ft)
Sch 60 24.61 mm (0.969 in) 560.78 mm (22.062 in) 355.28 kg/m (238.57 lb/ft)
Sch 80 30.96 mm (1.219 in) 548.08 mm (21.562 in) 442.11 kg/m (296.86 lb/ft)
Sch 100 38.89 mm (1.531 in) 532.22 mm (20.938 in) 547.74 kg/m (367.74 lb/ft)
Sch 120 46.02 mm (1.812 in) 517.96 mm (20.376 in) 640.07 kg/m (429.79 lb/ft)
Sch 140 52.37 mm (2.062 in) 505.26 mm (19.876 in) 720.19 kg/m (483.57 lb/ft)
Sch 160 59.54 mm (2.344 in) 490.92 mm (19.312 in) 808.27 kg/m (542.64 lb/ft)

Plain-end weight of carbon steel pipe, by the standard's own formula: 10.69 × (D − t) × t in lb/ft, with D and t in inches (0.0246615 × (D − t) × t in kg/m, in mm). Austenitic stainless weighs about 2% more.

Lay out on 24 inch pipe

The outside diameter and the wall of the chosen schedule go to the calculator, which opens with them filled in and draws without an account.

Pipe saddle (90° tee) 90° lobster back bend

Questions

What is the outside diameter of 24 inch pipe?
610 mm (24.000 in), in any schedule: it is the DN 600 pipe of ASME B36.10M. The wall changes with the schedule, and the inside diameter with it.
What is the wall thickness of 24 inch schedule 40 pipe?
17.48 mm (0.688 in), with an inside diameter of 575.04 mm (22.624 in); carbon steel pipe weighs 255.43 kg/m (171.45 lb/ft).
What is the difference between schedule 40 and 80 in 24 inch pipe?
The wall: 17.48 mm (0.688 in) in schedule 40 and 30.96 mm (1.219 in) in 80. The outside diameter is the same, so schedule 80 has the smaller bore -- 548.08 mm (21.562 in) against 575.04 mm (22.624 in) -- and weighs 442.11 kg/m (296.86 lb/ft) against 255.43 kg/m (171.45 lb/ft).