Skip to content

8 inch pipe (DN 200): outside diameter, wall thickness and weight by schedule

A 8 inch pipe (DN 200) has a 219.1 mm (8.625 in) outside diameter in every schedule: what changes is the wall, and with it the inside diameter and the weight. Designations that give the same wall share a row.

Schedule Wall ID Weight
Sch 5 / 5S 2.77 mm (0.109 in) 213.56 mm (8.407 in) 14.78 kg/m (9.92 lb/ft)
Sch 10 / 10S 3.76 mm (0.148 in) 211.58 mm (8.329 in) 19.97 kg/m (13.41 lb/ft)
Sch 20 6.35 mm (0.250 in) 206.40 mm (8.125 in) 33.32 kg/m (22.38 lb/ft)
Sch 30 7.04 mm (0.277 in) 205.02 mm (8.071 in) 36.82 kg/m (24.72 lb/ft)
Sch 40 / STD / 40S 8.18 mm (0.322 in) 202.74 mm (7.981 in) 42.55 kg/m (28.58 lb/ft)
Sch 60 10.31 mm (0.406 in) 198.48 mm (7.813 in) 53.09 kg/m (35.67 lb/ft)
Sch 80 / XS / 80S 12.70 mm (0.500 in) 193.70 mm (7.625 in) 64.64 kg/m (43.43 lb/ft)
Sch 100 15.09 mm (0.594 in) 188.92 mm (7.437 in) 75.92 kg/m (51.00 lb/ft)
Sch 120 18.26 mm (0.719 in) 182.58 mm (7.187 in) 90.44 kg/m (60.77 lb/ft)
Sch 140 20.62 mm (0.812 in) 177.86 mm (7.001 in) 100.93 kg/m (67.82 lb/ft)
XXS 22.23 mm (0.875 in) 174.64 mm (6.875 in) 107.93 kg/m (72.49 lb/ft)
Sch 160 23.01 mm (0.906 in) 173.08 mm (6.813 in) 111.27 kg/m (74.76 lb/ft)

Plain-end weight of carbon steel pipe, by the standard's own formula: 10.69 × (D − t) × t in lb/ft, with D and t in inches (0.0246615 × (D − t) × t in kg/m, in mm). Austenitic stainless weighs about 2% more.

Lay out on 8 inch pipe

The outside diameter and the wall of the chosen schedule go to the calculator, which opens with them filled in and draws without an account.

Pipe saddle (90° tee) 90° lobster back bend

Questions

What is the outside diameter of 8 inch pipe?
219.1 mm (8.625 in), in any schedule: it is the DN 200 pipe of ASME B36.10M. The wall changes with the schedule, and the inside diameter with it.
What is the wall thickness of 8 inch schedule 40 pipe?
8.18 mm (0.322 in), with an inside diameter of 202.74 mm (7.981 in); carbon steel pipe weighs 42.55 kg/m (28.58 lb/ft).
What is the difference between schedule 40 and 80 in 8 inch pipe?
The wall: 8.18 mm (0.322 in) in schedule 40 and 12.70 mm (0.500 in) in 80. The outside diameter is the same, so schedule 80 has the smaller bore -- 193.70 mm (7.625 in) against 202.74 mm (7.981 in) -- and weighs 64.64 kg/m (43.43 lb/ft) against 42.55 kg/m (28.58 lb/ft).